Under ~500 Wh class

A compact 300–500 Wh label is for phones, a USB camera recharge, LED lamps, a light CPAP night, and a short van laptop day. It is marginal for a full-day compressor fridge, and it does not cover a second fridge day with solar at zero. This site’s ceiling for the class is 512 Wh. The class name is approximate; a 512 Wh label is above 500 Wh. Sheets below were read 2026-11-06.

12 V and USB vs AC: η=0.90 is the inverter path. A fridge on the station’s 12 V port, phones on USB, and a router on USB-C use η=1.00. That 1.00 is a site planning convention. The station’s DC-port conversion loss is not modeled. Watt-hour math does not prove continuous watts or surge. That check is Surge traps. A light CPAP row below is one printed night so the class math can be checked. It is not therapy guidance. Pressure, humidity, and tube heat stay on CPAP. This page is not medical advice. Check your device manual and the label on your power brick for your exact model.
WattNeeds defaults, same as the calculator: DoD=0.90, buffer=0.15, AC inverter η=0.90, 12 V and USB η=1.00. Sizing up: nameplateWh = (whPerDay × days × 1.15) / (0.90 × η). Runtime check, buffer off: delivered = nameplate × 0.90 × η, then days = delivered ÷ load Wh. AC denominator is 0.81. DC denominator is 0.90.

What a label in this class delivers

Same order as js/calculator.js. Round the full quotient once, half-up, the way Math.round does. Do not round the middle steps and then keep going. DoD=0.90 is a planning fraction of the label. It is not a BMS guarantee. The 15% buffer is headroom, not a measured loss. The runtime check does not apply the buffer again on the way down.

300 Wh and 500 Wh are round planning labels. They are not a claim that a box is printed that way. The RIVER 2 Max manual prints 512 Wh (20 Ah, 25.6 V). That sheet is already the small-station example on 500 vs 1,000 Wh. Do not shop the sheet’s delivered watt-hours as if they were the round 500 label.

Label12 V / USB deliveredAC delivered
300 Wh, round300 × 0.90 = 270 Wh300 × 0.81 = 243 Wh
500 Wh, round500 × 0.90 = 450 Wh500 × 0.81 = 405 Wh
512 Wh, printed sheet512 × 0.90 = 460.8 → 461 Wh512 × 0.81 = 414.72 → 415 Wh

The 300 and 500 products are exact. 460.8 and 414.72 are the unrounded sheet products. Round those once for the display. Runtime on the sheet divides 460.8 or 414.72, not 461 or 415. The 415 Wh AC figure is the same product already on 500 vs 1,000 Wh. Do not shop 415 Wh as if it were the round label’s 405 Wh, or 461 Wh as if it were 450 Wh.

Class spans on this site, from the sizing walkthrough: results up to 512 Wh, then 513–1,152 Wh, then 1,153 Wh and up. A plan of 501 Wh is still this class. It is also 1 Wh over a round 500 label. Shop the buffered nameplate against the printed label, not the round class name. A miss that lands in 513–1,152 Wh is the ~1,000 Wh class.

Planning estimate, not a measurement. A round 300 Wh label times 0.90 is 270 Wh on 12 V and times 0.81 is 243 Wh on AC. A round 500 Wh label is 450 Wh on 12 V and 405 Wh on AC. A printed 512 Wh sheet is 460.8 Wh on 12 V, shown as 461, and 414.72 Wh on AC, shown as 415. Phones and four LED pucks are 84 Wh. The 12 V nameplate 107.333 rounds to 107 Wh, which a 300 Wh label covers. A CFX3-class camp day of 392 Wh on 12 V names to 500.889, shown as 501 Wh. A round 500 Wh label is short by 1 Wh. A 512 Wh sheet covers 501. A 6-minute 1,050 W microwave window is 105 Wh and names to 149 Wh. The energy fits a 300 Wh label. A 500 W rated inverter does not run 1,050 W.
EXAMPLE. 300 × 0.90 = 270 Wh on 12 V. 300 × 0.81 = 243 Wh on AC. 500 Wh is 450 / 405 Wh. The 512 Wh sheet is 460.8 / 414.72, shown as 461 / 415 Wh. Light day 107.333 rounds to 107 Wh. Camp day 500.889 rounds to 501 Wh. A round 500 is short by 1. Microwave window 105 Wh names to 149 Wh. 1,050 W is over a 500 W rated line.

Light day: phones and LEDs, no fridge

Solar = 0. No compressor. The phone row is the Apple 20 W USB-C adapter ceiling, the same 20 W × 1 h × 2 already on 500 vs 1,000 Wh. A phone often draws less, so 40 Wh is a ceiling. The lamps are four Stanpro 67168 pucks. The sheet rates the puck at 2.2 W, 12 V. Four pucks and 5 h are this day. The hub is not sized here. A camera battery on USB is the same kind of recharge as the phone ceiling. This stack does not add a camera watt-hour, because no camera sheet is in the count.

LoadBasisWh/dayPath
Two phonesApple 20 W USB-C adapter × 1 h × 2. Count and hours are this day.40USB, η=1.00
Four Stanpro 67168 pucks2.2 W × 4 × 5 h.4412 V, η=1.00
Light day40 + 44. No fridge.84One DC pass

All on 12 V and USB. Steps are load ÷ 1.00, × 1.15, ÷ 0.90.

DaysStepsExactNameplate
184.000 → 96.600 → nameplate107.333107 Wh
2168.000 → 193.200 → nameplate214.667215 Wh

84 × 1 × 1.15 / (0.90 × 1.00) = 107.333 → 107 Wh

84 × 2 × 1.15 / 0.90 = 214.667 → 215 Wh

Do not double the rounded day. 107 × 2 = 214. The two-day quotient is 214.667, which rounds to 215 Wh.

A 300 Wh label delivers 270 Wh on 12 V. 270 / 84 = 3.214 days, which is (270 / 84) × 24 = 77.143 hours at that day’s average. A 500 Wh label delivers 450 Wh: 450 / 84 = 5.357 days, 128.571 hours. A 512 Wh sheet delivers 460.8 Wh on 12 V: 460.8 / 84 = 5.486 days. Do not divide the rounded 461 Wh. Both buffered plans, 107 Wh and 215 Wh, sit under a 300 Wh label. Two days of this stack are not the reason to leave the class.

If the same 84 Wh moves onto AC bricks, one day is 84 × 1.15 / 0.81 = 119.259 → 119 Wh. Two days are 238.519 → 239 Wh. Do not double 119. 119 × 2 = 238. A 300 Wh label still covers both. AC runtime, buffer off: 243 / 84 = 2.893 days on a 300 Wh label, and 405 / 84 = 4.821 days on a 500 Wh label.

A short van laptop day is a different stack, already worked on 500 vs 1,000 Wh: one MacBook Air 13-inch (M3) recharge at the published 52.6 Wh pack, plus one Caframo Sirocco II on a timer step. 77.8 Wh names to 99.411 → 99 Wh. 103 Wh names to 131.611 → 132 Wh. Both sit under a 300 Wh label. The full parked day with the fridge is van daily Wh, and it is not this class.

One CFX3 day on 12 V can miss a round 500

Solar = 0. The fridge figure is the CFX3 35 test point, the same 282 Wh/day used on camping fridge. The sheet lists 0.98 Ah/h at 12 V DC, ambient 90°F, internal 39°F, volume 36 L. 0.98 × 12 × 24 = 282.24, published as 282 Wh/day. Dometic’s runtime method is usable battery Ah ÷ that Ah/h. Their lead-acid note is a different battery. It is not this site’s 0.90 DoD.

The same electrical table prints rated DC current 7.5 A, rated AC power 50 W, and rated AC current 0.78 A at 120 V. 7.5 × 12 = 90 W. 0.78 × 120 = 93.6 VA, which is volt-amps, not watts; real watts also depend on power factor, which is not supplied here. The 90 W DC rating, 93.6 VA AC apparent power and 50 W AC rating are distinct quantities; do not substitute them for the daily energy figure. This page does not average them and does not use any of them as the day. Average power at the test point is 282 / 24 = 11.75 W. 50 W × 24 h = 1,200 Wh is the rated AC input held all day, not this test point.

Three published ways to add the small loads. They are not the same day. The 40 Wh and 44 Wh rows are the cited ceilings above. The 50 Wh and 60 Wh rows are the weekend planning allowances on weekend camping (10 W × 5 h, and 60 Wh of phone charging). 320 Wh/day is a different band and is not used here.

Stack, solar = 0Wh at the loadsPathExactNameplate
Fridge only, 1 day28212 V, η=1.00360.333360 Wh
Fridge only, 1 day282AC, η=0.90400.370400 Wh
Cited gadgets, 1 day282 + 40 + 44 = 36612 V / USB, η=1.00467.667468 Wh
Weekend allowances, 1 day282 + 50 + 60 = 39212 V / USB, η=1.00500.889501 Wh
Weekend allowances, 1 day392AC, η=0.90556.543557 Wh
Cited gadgets, 2 days366 × 2 = 73212 V / USB, η=1.00935.333935 Wh
Weekend allowances, 2 days392 × 2 = 78412 V / USB, η=1.001,001.7781,002 Wh

282 × 1.15 / 0.90 = 360.333 → 360 Wh

366 × 1.15 / 0.90 = 467.667 → 468 Wh

392 × 1.15 / 0.90 = 500.889 → 501 Wh

392 × 1.15 / 0.81 = 556.543 → 557 Wh

Steps for the marginal 12 V day: 392.000 → 450.800 → 500.889. Do not double a rounded day. 468 × 2 = 936. The two-day cited stack is 935.333, which rounds to 935 Wh. 501 × 2 = 1,002 happens to match the two-day weekend quotient’s rounded result. Size from 1,001.778 anyway.

A fridge-only test point fits a round 500 Wh label on both paths (360 Wh and 400 Wh). It does not fit a round 300 Wh label. On 12 V a 300 Wh label delivers 270 Wh, and 270 / 282 = 0.957 of the test point. That is short of one fridge day before phones or lamps.

The cited 366 Wh day on 12 V names to 468 Wh. A 500 Wh label covers it. Label headroom is 500 − 468 = 32 Wh. Runtime, buffer off: 450 / 366 = 1.230 days, and (450 / 366) × 24 = 29.508 hours. That is one day. It is not a second day. Two days name to 935 Wh, which is over 500 Wh, over 512 Wh, and inside the ~1,000 Wh class.

The weekend 392 Wh day on 12 V names to 501 Wh. A round 500 Wh label is short by 1 Wh. The class ceiling is 512 Wh, so 501 Wh is still this class, and a 512 Wh sheet covers it because 512 ≥ 501. On AC that same day is 557 Wh, which is above 512 Wh and is the ~1,000 Wh class. Runtime on 12 V, buffer off: 450 / 392 = 1.148 days, (450 / 392) × 24 = 27.551 hours. The unbuffered energy covers one day. The buffer is what pushes the shopping number to 501 Wh. On the sheet, divide the unrounded product: 460.8 / 392 = 1.176 days. Do not divide 461.

Plugging the fridge into the inverter changes the path. The cited phones and pucks stay on USB and 12 V (84 Wh, η=1.00). The 282 Wh test point moves to η=0.90. Add the full quotients, then round once. This is the same split already on 500 vs 1,000. The rounded passes are 400 + 107 = 507. The full sum is 507.703703…, shown as 507.704, which rounds to 508 Wh. The three-decimal displays add to 400.370 + 107.333 = 507.703, one thousandth under that 507.704.

282 × 1.15 / 0.81 + 84 × 1.15 / 0.90 = 400.370370… + 107.333333… = 507.703703… → 508 Wh

A round 500 Wh label is short of 508 Wh by 8 Wh. A 512 Wh sheet covers it. 508 Wh is inside this class. It is not a pass on a box whose label is 500 Wh. Two of the 12 V fridge days are where ~1,000 Wh is the floor. The loaded camping day with a laptop is a different stack on weekend camping.

Overnight: a light CPAP row, or lamps and a router

Two nights that are not a fridge. Solar = 0. The CPAP figures are the AirSense 10 rows already on CPAP, from ResMed’s battery guide (198103/7, 2018-08). The worked pressure is the printed 10 cm H2O column. It is not a recommended setting. This page does not set pressure, humidity, or tube heat, and it does not tell anyone to remove a humidifier. The SlimLine-only row is the light night so the class can be checked. The heated-tube-plus-humidifier row is the night that leaves the class.

Printed row at 10 cm H2OWh for 8 hPathExactNameplate
SlimLine only. 0.93 A × 12 V × 8 h.89.28DC converter, η=1.00114.080114 Wh
SlimLine only, no recharge, 2 nights89.28DC converter, η=1.00228.160228 Wh
SlimLine only89.28AC inverter, η=0.90126.756127 Wh
ClimateLineAir at 30°C, humidifier setting 8. 4.92 A × 12 V × 8 h.472.32DC converter, η=1.00603.520604 Wh

89.28 × 1.15 / 0.90 = 114.080 → 114 Wh

89.28 × 2 × 1.15 / 0.90 = 228.160 → 228 Wh

472.32 × 1.15 / 0.90 = 603.520 → 604 Wh

A 300 Wh label delivers 270 Wh on the DC convention. 270 / 89.28 = 3.024 SlimLine-only nights. A 500 Wh label delivers 450 Wh: 450 / 89.28 = 5.040 nights, the same quotient already on the CPAP page. The buffered plans, 114 Wh and 228 Wh, sit under a 300 Wh label. The heavy row names to 604 Wh. That is over a 300 Wh label, over a 500 Wh label, over a 512 Wh sheet, and over this class ceiling. It is inside the ~1,000 Wh class. Read ResMed’s inverter guidance on the CPAP page before an AC path. The AC rows there are the site formula, not approval of a heated humidifier on a station outlet.

The other night is lamps and a router, no fridge and no CPAP. It is the stack on 500 vs 1,000 Wh. The house-fridge sticker day is home outage, and it does not fit this class. Lamps are on AC outlets. The router and the phones stay on USB.

LoadBasisWhPath
Two GE Basic A19 lampsThe GE page prints wattage 8.5 W at 120 V, and “60 Watt replacement” as the old-bulb line. 8.5 W × 2 × 6 h. Six hours is this night, not GE’s 3 h/day cost example. The dollar line on that page is not used.102AC, η=0.90
GL.iNet GL-MT3000The product page prints power consumption as <8 W. Power input is Type-C, 5 V / 3 A. 5 × 3 = 15 W is the port rating, not the night. Ceiling: 8 W × 12 h. Twelve hours is this window.96USB, η=1.00
Two phonesSame 20 W × 1 h × 2 ceiling as the light day.40USB, η=1.00
NightUSB 96 + 40 = 136. AC lamps 102.238Two passes

USB pass: 136 × 1.15 / 0.90 = 173.778, which rounds to 174 Wh alone. AC pass: 102 × 1.15 / 0.81 = 144.815, which rounds to 145 Wh alone. Add the exact passes. 173.778 + 144.815 = 318.593 → 319 Wh. Two nights: 637.185 → 637 Wh. Do not double the rounded night. 319 × 2 = 638.

1 night: 136 × 1.15 / 0.90 + 102 × 1.15 / 0.81 = 173.778 + 144.815 = 318.593 → 319 Wh

Battery draw per night: 136 + 102 / 0.90 = 249.333 Wh. A 300 Wh label covers (300 × 0.90) / 249.333 = 1.083 nights. A 500 Wh label covers 1.805 nights, (450 / 249.333) × 24 = 43.316 hours. The unbuffered energy covers one night on a 300 Wh label. The buffered plan is 319 Wh, which is 19 Wh over that label and under a 500 Wh label. A 512 Wh sheet covers 319 Wh. Two nights (637 Wh) miss 300, 500, and 512. If the router and the phones move onto AC bricks, the whole 238 Wh uses η=0.90. One night is 337.901 → 338 Wh. Same decision: 300 is short, 500 covers one night.

A microwave fits the watt-hours and misses the inverter

Stored energy can pass while the inverter’s continuous line fails. A magnetron cook lasts minutes. The peak line is not those minutes. No surge multiple is invented here. No scope trace. The same oven is on 500 vs 1,000 Wh and on surge traps.

The Comfee manual for AM720C2RA-R, AM720C2RA-A, and AM720C2RA-G prints 120 V, 60 Hz, rated microwave input 1,050 W, rated microwave output 700 W, capacity 0.7 cu ft. 700 W is cooking output. The wall draw on that sheet is 1,050 W. The sheet does not print a power factor, so this page does not invent one. Six minutes is this page’s reheat window, not a cook on the sheet. The manual’s own maximum time is longer.

1,050 W × (6/60) h = 105 Wh

105 × 1.15 / 0.81 = 149.074 → 149 Wh

A 300 Wh label delivers 243 Wh on AC, which is 243 / 105 = 2.314 of those windows. A 500 Wh label delivers 405 Wh, 3.857 windows. A 512 Wh sheet delivers 414.72 Wh on AC, 414.72 / 105 = 3.950 windows. Do not divide the rounded 415 Wh. All three labels store one cook. None of those quotients turn the oven on.

On the RIVER 2 Max sheet, read 2026-11-06, AC output is pure sine, 500 W total (1,000 W peak), 120 V. Duration not published. That peak is not a timed pass. 1,050 W is over the 500 W rated line, over the 1,000 W peak, and over that manual’s X-Boost ceiling of 1,000 W. The extra 12 Wh on a 512 Wh sheet does not change the 500 W line. Buying the next watt-hour class is a different inverter. Use cords rated for the load; don't daisy-chain extension cords or power strips. Do not backfeed a breaker panel. The oven plugs into the station, not into a house circuit through the panel.

Inverter watts and charge input are not the Wh label

One small-station manual. The round 300 and 500 labels above are the energy comparison. This sheet is the watts and the input ceilings. It is not a ranking, and it is not a 500 Wh label.

LineRIVER 2 Max manual, read 2026-11-06
Printed capacity512 Wh (20 Ah, 25.6 V). Not a 500 Wh label and not a 300 Wh label.
Cell chemistry / cycle lifeLFP, 3,000 cycles to 80%+ capacity.
AC outputPure sine, 500 W total (1,000 W peak), 120 V. Duration not published. That peak is not a timed pass.
X-BoostDevices rated up to 1,000 W. Not for appliances with voltage protection. Suitable for heating and motor-driven devices; the manual says to test. The manual's FAQ says to keep the sum of all loads under the rated power. EcoFlow's X-Boost page says it "marginally reduces voltage"; it gives no volt figure. WattNeeds sizing rule, stricter than the manual's "heating and motor-driven devices" line, same as 500 vs 1,000 Wh: voltage-reduction lift modes are for resistive heating loads only. Reduced voltage can stall or overheat motor and compressor loads. Not a surge rating. Do not size on it.
Solar input11–50 V, 13 A, 220 W max. Keep panel voltage under the 50 V input limit. 220 W is a ceiling, not a day’s harvest. See solar vs battery.
Car charge input12 V / 24 V, 8 A, 100 W max.
AC chargeX-Stream 660 W max, and “fully charged in 1 hour.” 512 Wh / 1 h = 512 W, which sits under 660 W. Do not turn 660 W × 1 h into a 660 Wh battery.
12 V output12.6 V, 10 A / 3 A / 3 A, 126 W max. 126 W is the printed total, not 126 W from each of those currents. That ceiling is not the fridge’s 11.75 W average.

The manual prints weight as approximately 6.1 kg (13.4 lb). It does not print a price. This page does not divide Wh by kilograms. A lighter station is not automatically the better buy, and a heavier one is not automatically the right inverter.

Where this class is enough

“Covers” means that label is at least the buffered nameplate. The microwave row stores the energy and still fails the 500 W line above.

Buffered planNameplate300 Wh label500 Wh label512 Wh sheet
Light day, 84 Wh, 1 day, 12 V107 WhCoversCoversCovers
Light day, 2 days, 12 V, solar = 0215 WhCoversCoversCovers
Light day, all on AC, 2 days239 WhCoversCoversCovers
Van laptop + fan, published 6 h / 12 h99 Wh / 132 WhCoversCoversCovers
Fridge only, 282 Wh, 1 day, 12 V360 WhShortCoversCovers
Fridge only, 1 day, AC400 WhShortCoversCovers
Cited camp, 366 Wh, 1 day, 12 V468 WhShortCovers. Headroom 32 Wh. Not a second day.Covers
Weekend camp, 392 Wh, 1 day, 12 V501 WhShortShort by 1 Wh. Class ceiling is 512.Covers
Weekend camp, 392 Wh, 1 day, AC557 WhShortShort. Above the class ceiling.Short. ~1,000 Wh class.
Fridge on AC, 84 Wh still on 12 V, 1 day508 WhShortShort by 8 Wh. Class ceiling is 512.Covers
Cited camp, 2 days, 12 V, solar = 0935 WhShortShortShort. ~1,000 Wh class.
SlimLine-only night, DC, 1 night114 WhCoversCoversCovers
SlimLine-only, 2 nights, DC228 WhCoversCoversCovers
Heated tube + humidifier 8, 1 night, DC604 WhShortShortShort. Above the class ceiling.
Outage night, USB plus AC lamps, 1 night319 WhShort by 19 Wh. Unbuffered runtime is 1.083 nights.CoversCovers
Outage, 2 nights, solar = 0637 WhShortShortShort
One 6 min microwave window149 WhEnergy covers. 1,050 W does not run on a 500 W rated line.Energy covers. The 500 W line still fails.Energy covers. The 500 W line still fails.

A round 300 Wh label is enough for this phone-and-LED day, for two of those days, for the published laptop-and-fan van day, and for one or two SlimLine-only nights on the DC convention. It is not enough for the CFX3 test point, even with nothing else on. A round 500 Wh label covers one fridge-only test-point day, the cited 366 Wh camp day on 12 V, and one lamp-and-router night. It is short of the weekend 392 Wh day by 1 Wh on 12 V and short of the AC-fridge split by 8 Wh. A printed 512 Wh sheet covers those two one-day plans and still misses a second fridge day. A 1,050 W microwave is a watts problem on the 500 W line. The watt-hour class does not fix it.

Related: 500 vs 1,000 Wh · ~1,000 Wh class · camping fridge · surge traps · CPAP · home outage · weekend camping · van daily Wh

Wh calculator — one η per pass. 12 V and USB: set inverter efficiency to 1.00. AC outlets: leave η at 0.90. nameplate = (Wh/day × days × 1.15) / (0.90 × η).